About 40 minutes · 3 things to learn By the end you can…
Define electric power and the watt and use P = VI = I²R = V²/R (interrelation of P, V, I and R), including power ratings such as "220 V, 60 W".
Calculate electrical energy in J, W h and kW h (1 kW h = 3.6 × 10⁶ J) and the cost of electricity.
Choose a fuse rating from an appliance's power and voltage.
Your electricity bill does not charge you for "current" or for "volts". It charges you for units — and a geyser running for half an hour can use more units than a ceiling fan running all evening. What is a "unit", and how do you work out the bill?
Quick reminder (Class 9, Work and Energy).Power is the rate of doing work — also the rate at which energy is used. Its unit is the watt (W): 1 W = 1 J/s; 1 kW = 1000 W.
Electric power
In Topic 6, the energy supplied in time t was VIt. Dividing by t gives the rate of using (dissipating) electric energy — the electric power:
P=VISwipe to see the whole equation →
Using Ohm's law (V=IR, or I=RV), the same power can be written in two more ways:
P=VI=I2R=RV2Swipe to see the whole equation →
These three forms are the interrelation between P, V, I and R. Choose the one that uses the quantities you are given:
You know
Use
V and I
P=VI
I and R
P=I2R
V and R
P=RV2
The SI unit of electric power is the watt (W) — the power used by a device that carries 1 A when operated at a p.d. of 1 V:
1W=1V×1A=1V ASwipe to see the whole equation →
The watt is small, so in practice we often use the kilowatt (1 kW = 1000 W).
Power ratings
An appliance is labelled with its rating — for example "220 V, 60 W". This means it uses 60 W when connected to 220 V. From the rating you can find:
its normal current: I=VP;
its resistance: R=PV2 (taken as constant).
If the same appliance is run on a different p.d., and we take its resistance as unchanged (as textbook problems do), its power changes: P=RV2. Half the p.d. gives one-quarter of the power. So a "100 W" bulb uses 100 W only at its rated voltage.
Electrical energy and the "unit"
Electrical energy used = power × time:
E=P×tSwipe to see the whole equation →
In joules: P in W, t in s.
In watt hours (W h): P in W, t in h. 1 W h is the energy of 1 W kept up for 1 hour.
In kilowatt hours (kW h): P in kW, t in h. The kilowatt hour is the commercial unit of electrical energy — the "unit" on your bill.
1kW h=1000W×3600s=3.6×106W s=3.6×106JSwipe to see the whole equation →
Cost of electricity = number of units (kW h) × price per unit.
Choosing a fuse
The fuse (Topic 6) must let the normal current through but melt if the current rises well above it. So:
find the normal current: I=VP;
choose the standard rating just above it (ratings 1 A, 2 A, 3 A, 5 A, 10 A …).
Visuals
Rating plate and electricity meterConnect what is printed on an appliance and on the bill to the formulas.
Worked examples
Worked example 1
Power from p.d. and current
Question. A mixer-grinder draws 2.5 A from the 220 V mains. What is its power?
Given:V=220V; I=2.5A. Asked:P.
Concept used:P=VI (this topic). Why it applies: p.d. and current are given.
1
Formula.
P=VISwipe to see the whole equation →
2
Substitute.
P=220V×2.5ASwipe to see the whole equation →
3
Multiply (V × A = W).
P=550WSwipe to see the whole equation →
Check: in kilowatts, 550 W = 0.55 kW — a sensible size for a kitchen appliance ✔.
AnswerP=550W
Worked example 2
Reading a rating
Question. A lamp is rated "220 V, 44 W". Find (a) the current it draws at its rated voltage, (b) its resistance, (c) the power it would use if the supply p.d. were halved (resistance unchanged).
Given:V=220V; P=44W. Asked:I; R; new P at 110 V.
Concept used:P=VI; P=RV2 (this topic). Why it applies: a rating gives P at a stated V.
1
(a) Current.
I=VP=220V44W=0.2ASwipe to see the whole equation →
2
(b) Resistance.
R=PV2=44W(220V)2=4448400Ω=1100ΩSwipe to see the whole equation →
3
(c) Half the p.d. → P=RV2 with the same R, so the power becomes (21)2=41 of 44 W.
P=444W=11WSwipe to see the whole equation →
Check: (b) by Ohm's law, R=IV=0.2220=1100Ω ✔.
Answer(a) 0.2A (b) 1100Ω (c) 11W
Common trap: (c) "half the p.d., half the power" → 22 W. With R fixed, the current halves too, so the power falls to a quarter.
Worked example 3
Units and the bill
Question. A 1.5 kW air conditioner runs for 6 hours a day for 30 days. How many units does it use, and what is the cost at Rs 7 per unit?
Given:P=1.5kW; t=6h/day×30days; rate Rs 7 per kW h. Asked: energy in kW h; cost.
Concept used:E=Pt in kW h; cost = units × rate (this topic). Why it applies: the bill counts kW h.
1
Total time.
t=6h×30=180hSwipe to see the whole equation →
2
Energy in kW h.
E=1.5kW×180h=270kW hSwipe to see the whole equation →
3
Cost.
Cost=270×Rs 7=Rs 1890Swipe to see the whole equation →
Check: in one day it uses 1.5×6=9 units (Rs 63); 63×30=1890 ✔.
Answer270units (kW h), costing Rs 1890
Common trap: using 1500 W with hours (that gives 270000 W h, not units). Units are kW × h.
Worked example 4
Which uses more energy?
Question. Which uses more electrical energy: a 2 kW geyser used for 20 minutes, or a 75 W ceiling fan used for 8 hours? Give both in kW h and in joules.
Given: geyser 2 kW, 20 min; fan 75 W, 8 h. Asked: compare energies.
Concept used:E=Pt; 1 kW h = 3.6×106 J (this topic). Why it applies: energy depends on both power and time.
1
Geyser — 20 min =31 h.
E=2kW×31h=32kW h≈0.67kW hSwipe to see the whole equation →
2
Fan — 75 W = 0.075 kW.
E=0.075kW×8h=0.6kW hSwipe to see the whole equation →
3
In joules. Geyser: 32×3.6×106=2.4×106 J. Fan: 0.6×3.6×106=2.16×106 J.
Check: the geyser's power is about 27 times the fan's, but it runs for only 241 of the time — so it should use slightly more ✔.
AnswerThe geyser uses more: 2.4×106J (about 0.67 kW h) against the fan's 2.16×106J (0.6 kW h).
Common trap: deciding by power alone ("2 kW is bigger"). Energy = power × time.
Worked example 5
Choosing a fuse
Question. A microwave oven is rated 1.32 kW, 220 V. Fuses are available in ratings of 2 A, 3 A, 5 A and 10 A. Which should be used?
Given:P=1.32kW=1320W; V=220V. Asked: the fuse rating.
Concept used:I=VP; choose the rating just above the normal current (this topic). Why it applies: the fuse must carry the normal current but melt above it.
1
Normal current.
I=VP=220V1320W=6ASwipe to see the whole equation →
2
Ratings above 6 A → only 10 A. (A 5 A fuse would melt every time the oven is used.)
Check: 6 A is less than 10 A, so normal use is safe, and a large fault current would still melt the fuse ✔.
AnswerThe normal current is 6 A, so use the 10A fuse.
Common trap: choosing the 5 A fuse because "5 is closest to 6". The rating must be above the normal current.
5 examples · they get harder as you go
Quick check
Answer without scrolling up
Quick check · 1 of 3MCQ1 mark
The kilowatt hour (kW h) is a unit of:
Power is in watts or kilowatts; kW × h is energy.
1 kW h = 3.6×106 J — the "unit" on the bill.
Current is in amperes.
P.d. is in volts.
Quick check · 2 of 3MCQ1 mark
Two bulbs are rated "220 V, 20 W" and "220 V, 100 W". Which statement is correct?
R=PV2: a larger power at the same voltage means a smaller resistance.
Different powers at the same voltage need different resistances.
R=202202=2420Ω against 1002202=484Ω.
R=PV2 gives it.
Quick check · 3 of 3Numerical2 marks
A current of 3 A flows through a 15 Ω resistor. Find the power used in it.
Answer:P=I2R=32×15=9×15=135 W.
With I and R given, P=I2R is the direct route; square the current first.
Did you get it?
Key points
Electric power = rate of using electrical energy: P=VI=I2R=RV2. Unit watt: 1 W = 1 V × 1 A; 1 kW = 1000 W.
A rating "V, P" gives the current I=VP and the resistance R=PV2; at another p.d. the power changes as V2.
EnergyE=Pt: J (W × s), W h, or kW h (the commercial "unit"); 1 kW h = 3.6 × 10⁶ J. Cost = units × rate.
Fuse choice: normal current VP, then the standard rating just above it.